3 Phase Online Uninterruptible Power Supply High Frequency 10KVA-200KVA
PT33
3 phase high frequency online uninterruptible power supply. Three-phase In/Three-phase Out.
Country of Origin
China
Stock Time
35Day
Quantity:
PT33 is a 3 phase high frequency UPS with 3-phase in and 3-phase out. This 3-phase UPS is ranging from 10Kva to 200Kva. Features include high reliability, high efficiency, and good power quality, and are applicable to the following various scenarios:
Features:
•Pluggable power module design with front access to decrease MTTR, parallel redundancy capability for power guarantee
•Power walk-in function. Support parallel operation with common battery
•Dual mains inputs
•Built-in 4 switches induding Mains input, bypass input,outputand maintenance bypass switch
•Flexible battery configuration and adjustable charging current
•Outputpower factor 0.9(10K-20K); Output power factor1.0 (30-200K)Active power factor correction in all phases
•Built-in 7"touch LCD screen for comprehensive infomation
•Emergency power off function(EPO)
•Generator compatible
•50Hz/60Hz frequency converter mode
Techinical Specifications
| Model | PT33-10KVA | PT33-15KVA | PT33-20KVA | PT33-30KVA | PT33-40KVA | PT33-60KVA | |
| PHASE | 3-phase in/3-phase out | ||||||
| CABINET CAPACITY | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | |
| PARALLEL CAPABILITY | N/A | 4 | |||||
| INPUT | |||||||
| Nominal Voltage | 3 x 380Vac (3Ph+N+PE) | 3 x 360/380/400/415 Vac (3Ph+N) | |||||
| Voltage Range | 190-520Vac(3Ph)@50% load; 305-478Vac(3Ph)@100% load | 110-300Vac@50% load; 176-276Vac@100% load | |||||
| Frequency Range | 46-54Hz or 56-64Hz | 40-70Hz | |||||
| Power Factor | >=0.99@100%load | ||||||
| Harmonic Distortion(THDi) | <4$ at full load | ||||||
| OUTPUT | |||||||
| Nominal Voltage | 3 x 360/380/400/415 Vac (3Ph+N) | ||||||
| AC Voltage Regulation (Batt Mode) | ±1% | ||||||
| Frequency Range (Batt Mode) | 50/60Hz±0.1% | 50/60Hz±1% | |||||
| Frequency Range (Synchronized range) | 46Hz-54Hz or 56Hz-64Hz | ||||||
| Overload Capability | 100-110% for 1 hour,111%~125% for10mins, 126%~150% for 1 min and >150% for inmmediately shutdown | ||||||
| Transfer Time | AC Mode to Batt Mode | Zero | |||||
| Inverter to Bypass | Zero | ||||||
| Harmonic Distortion | <=2%THD(Linear Load); <=4%THD(Non-inearLoad) | ||||||
| EFFICIENCY | |||||||
| AC Mode | 90.5% | 91.5% | 95.5% | ||||
| ECO Mode | 96.5% | 98.5% | |||||
| Battery Mode | 87% | 88% | 94.5% | ||||
Specifications 100KVA-200KVA
| Model | PT33-100KVA | PT33-120KVA | PT33-180KVA | PT33-200KVA | |
| PHASE | 3-phase in/3-phase out | ||||
| CABINET CAPACITY | 100KVA | 120KVA | 180KVA | 200KVA | |
| BATTERY TYPE | Extemal Battery | ||||
| PARALLEL CAPABILITY | 4 | ||||
| INPUT | |||||
| Nominal Voltage | 3 x 380/400/415 Vac (3Ph+N) | ||||
| Voltage Range | 110-300Vac@50% load; 176-276Vac@100% load | ||||
| Frequency Range | 40-70Hz | ||||
| Power Factor | >=0.99@100%load | ||||
| Harmonic Distortion(THDi) | <4$ at full load | ||||
| OUTPUT | |||||
| Nominal Voltage | 3 x380/400/415 Vac (3Ph+N) | ||||
| Voltage Regulation (Steady state) | <=1% Typical (balanced load) <=2% Typical (unbalanced load) | ||||
| Frequency Range (Batt Mode) | 50/60Hz | ||||
| Frequency Range (Synchronized range) | 46Hz-54Hz or 56Hz-64Hz | ||||
| Overload Capability | ≤110% for 1 hour,111%~125% for10mins, 126%~150% for 1 min and >150% for 200ms | ||||
| Harmonic Distortion | <=2%THD(Linear Load); <=4%THD(Non-inearLoad) | ||||
| EFFICIENCY | |||||
| AC Mode | 95.5% | ||||
| ECO Mode | 98.5% | ||||
| Battery Mode | 94.5% | ||||